Mono double glass solar cell panels bifacial panels 330W 340W 350W photovolatic modules.
- Dongke
- HANGZHOU,CHINA
- 15-20DAYS
- 1MW/Month
Key Features:
Improved Durability and Reliability
Double tempered glass increases the module robustness to mini
mize micro-cracks
PID Free and Snail Free
Without backsheet and frame reduces the water permeability and
PID risks.
Good Performance In low Irradiance
Excellent power generation in low radiation provides better perfo
rmance in dawn, dusk and no-sun days to create more value for
customers.
Reduced System Cost
1000V higher maximum system voltage reduces BOS cost.
Longer Lifetime
Less annual power loss of 0.5% and provide 30 years performance
warranty
World Insurance
CHUBB insurance from USA
Mono double glass solar cell panels bifacial panels 330W 340W 350W photovolatic modules.
Key Features:
Improved Durability and Reliability
Double tempered glass increases the module robustness to mini
mize micro-cracks
PID Free and Snail Free
Without backsheet and frame reduces the water permeability and
PID risks.
Good Performance In low Irradiance
Excellent power generation in low radiation provides better perfo
rmance in dawn, dusk and no-sun days to create more value for
customers.
Reduced System Cost
1000V higher maximum system voltage reduces BOS cost.
Longer Lifetime
Less annual power loss of 0.5% and provide 30 years performance
World Insurance
CHUBB insurance from USA
Warranty
12 years limited workmanship warranty.
No less than 97.5%output power in the first year.
No more than 0.5% annual declination since the second year.
30 year warranty at 83% power output.
Product liability and E&O insurance has been covered by Chubb
Insurance
Typical electrical characteristics
Maximum power(Pm)
| W | 330W | 340W | 350W |
Optimum Operating Voltage(Vm)
| V | 37.65 | 38.02 | 38.69 |
Optimum Operating Current (Im) | A | 8.77 | 8.95 | 9.05 |
Open-circuit Voltage (Voc)
| V | 46.45 | 46.79 | 47.35 |
Short-circuit Current (Isc)
| A | 9.23 | 9.37 | 9.50 |
Cell Efficiency
| % | 19.10 | 19.80 | 20.30 |
Module efficiency
| % | 16.90 | 17.41 | 17.93 |
STC (Standard Test Condition): Irradiance 1000W/m2, Module Temperature 25℃, AM=1.5